csirt@kutim:~/threat-intel/cve/CVE-2026-64510

Katalog CVE

CVSS 7.0 · High EPSS 0,15%

Skor CVSS 3.1 7.0 (High) menurut CNA.

Deskripsi (NVD)

In the Linux kernel, the following vulnerability has been resolved: ACPI: NFIT: core: Fix acpi_nfit_init() error cleanup If acpi_nfit_init() fails after adding the acpi_desc object to the acpi_descs list, that object is never removed from that list because the acpi_nfit_shutdown() devm action is not added for the NFIT device in that case. Next, the acpi_nfit_init() failure causes acpi_nfit_probe() to fail, the acpi_desc object is freed, and a dangling pointer is left behind in the acpi_descs. Any subsequent ACPI Machine Check Exception will trigger nfit_handle_mce() which iterates over acpi_descs and so a use-after-free will occur. Moreover, if acpi_nfit_probe() returns 0 after installing a notify handler for the NFIT device and without allocating the acpi_desc object and setting the NFIT device's driver data pointer, the acpi_desc object will be allocated by acpi_nfit_update_notify() and acpi_nfit_init() will be called to initialize it. Regardless of whether or not acpi_nfit_init() fails in that case, the acpi_nfit_shutdown() devm action is not added for the NFIT device and acpi_desc is never removed from the acpi_descs list. If the acpi_desc object is freed subsequently on driver removal, any subsequent ACPI MCE will lead to a use-after-free like in the previous case. To address the first issue mentioned above, make acpi_nfit_probe() call acpi_nfit_shutdown() directly on acpi_nfit_init() failures and to address the other one, add a remove callback to the driver and make it call acpi_nfit_shutdown(). Also, since it is now possible to pass NULL to acpi_nfit_shutdown() or the acpi_desc object passed to it may not have been initialized, add checks against NULL for acpi_desc and its nvdimm_bus field to that function and make acpi_nfit_unregister() clear the latter after unregistering the NVDIMM bus.

Rincian

Terbit di NVD
25 Juli 2026
Terakhir diubah
17 Agustus 2026
Status NVD
Received
CVSS 3.1
7.0 (High), sumber CNA
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
EPSS (30 hari)
0,15% peluang dieksploitasi; lebih tinggi dari 3,8% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.