csirt@kutim:~/threat-intel/cve/CVE-2026-57032

Katalog CVE

CVSS 6.5 · Medium EPSS 0,42%

Kerentanan Improper Handling of Undefined Parameters pada juniper junos. Skor CVSS 3.1 6.5 (Medium) menurut juniper.net.

Deskripsi (NVD)

An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of-Service (DoS). If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted.  The following log message can be seen when this issue happens: agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor> This issue affects Junos OS on EX2300, EX3400, EX4000, EX4100 and EX4400 devices: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S8, * 24.2 versions before 24.2R2-S5, * 24.4 versions before 24.4R2.

Rincian

Terbit di NVD
9 Juli 2026
Terakhir diubah
13 Juli 2026
Status NVD
Analyzed
CVSS 3.1
6.5 (Medium), sumber juniper.net
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-236: Improper Handling of Undefined Parameters
EPSS (30 hari)
0,42% peluang dieksploitasi; lebih tinggi dari 34,5% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
juniper junos Semua versi sebelum 23.2
juniper junos Versi 23.2
juniper junos Versi 23.2 r1
juniper junos Versi 23.2 r1-s1
juniper junos Versi 23.2 r1-s2
juniper junos Versi 23.2 r2
juniper junos Versi 23.2 r2-s1
juniper junos Versi 23.2 r2-s2
juniper junos Versi 23.2 r2-s3
juniper junos Versi 23.2 r2-s4
juniper junos Versi 23.2 r2-s5
juniper junos Versi 23.2 r2-s6
juniper junos Versi 23.4
juniper junos Versi 23.4 r1
juniper junos Versi 23.4 r1-s1
juniper junos Versi 23.4 r1-s2
juniper junos Versi 23.4 r2
juniper junos Versi 23.4 r2-s1
juniper junos Versi 23.4 r2-s2
juniper junos Versi 23.4 r2-s3
juniper junos Versi 23.4 r2-s4
juniper junos Versi 23.4 r2-s5
juniper junos Versi 23.4 r2-s6
juniper junos Versi 23.4 r2-s7
juniper junos Versi 24.2
juniper junos Versi 24.2 r1
juniper junos Versi 24.2 r1-s1
juniper junos Versi 24.2 r1-s2
juniper junos Versi 24.2 r2
juniper junos Versi 24.2 r2-s1
juniper junos Versi 24.2 r2-s2
juniper junos Versi 24.2 r2-s3
juniper junos Versi 24.2 r2-s4
juniper junos Versi 24.4
juniper junos Versi 24.4 r1
juniper junos Versi 24.4 r1-s2
juniper junos Versi 24.4 r1-s3

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.