csirt@kutim:~/threat-intel/cve/CVE-2026-45255

Katalog CVE

CVSS 7.5 · High EPSS 0,34%

Kerentanan Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') pada freebsd. Skor CVSS 3.1 7.5 (High) menurut CISA ADP.

Deskripsi (NVD)

When bsdinstall or bsdconfig are prompted to scan for nearby Wi-Fi networks, they build up a list of network names and use bsddialog(1) to prompt the user to select a network. This is implemented using a shell script, and the code which handled network names was not careful to prevent expansion by the shell. As a result, a suitably crafted network name can be used to execute commands via a subshell. The problem can be exploited to execute code as root on the system running bsdinstall or bsdconfig. The attacker would need to create an access point with a specially crafted name and be within range of a Wi-Fi scan. Note that bsdinstall and bsdconfig are vulnerable as soon as the user prompts them to scan for nearby networks; they do not need to actually select the malicious network.

Rincian

Terbit di NVD
21 Mei 2026
Terakhir diubah
23 Juli 2026
Status NVD
Analyzed
CVSS 3.1
7.5 (High), sumber CISA ADP
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
EPSS (30 hari)
0,34% peluang dieksploitasi; lebih tinggi dari 26,0% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
freebsd freebsd Versi 14.3
freebsd freebsd Versi 14.3 p1
freebsd freebsd Versi 14.3 p10
freebsd freebsd Versi 14.3 p11
freebsd freebsd Versi 14.3 p12
freebsd freebsd Versi 14.3 p13
freebsd freebsd Versi 14.3 p2
freebsd freebsd Versi 14.3 p3
freebsd freebsd Versi 14.3 p4
freebsd freebsd Versi 14.3 p5
freebsd freebsd Versi 14.3 p6
freebsd freebsd Versi 14.3 p7
freebsd freebsd Versi 14.3 p8
freebsd freebsd Versi 14.3 p9
freebsd freebsd Versi 14.4
freebsd freebsd Versi 14.4 p1
freebsd freebsd Versi 14.4 p2
freebsd freebsd Versi 14.4 p3
freebsd freebsd Versi 14.4 p4
freebsd freebsd Versi 14.4 rc1
freebsd freebsd Versi 15.0
freebsd freebsd Versi 15.0 p1
freebsd freebsd Versi 15.0 p2
freebsd freebsd Versi 15.0 p3
freebsd freebsd Versi 15.0 p4
freebsd freebsd Versi 15.0 p5
freebsd freebsd Versi 15.0 p6
freebsd freebsd Versi 15.0 p7
freebsd freebsd Versi 15.0 p8

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.