csirt@kutim:~/threat-intel/cve/CVE-2026-4157

Katalog CVE

CVSS 7.5 · High EPSS 1,3%

Kerentanan Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') pada chargepoint home flex cph50 firmware. Skor CVSS 3.0 7.5 (High) menurut trendmicro.com.

Deskripsi (NVD)

ChargePoint Home Flex revssh Service Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OCPP messages. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-26338.

Rincian

Terbit di NVD
11 April 2026
Terakhir diubah
17 Juni 2026
Status NVD
Analyzed
CVSS 3.0
7.5 (High), sumber trendmicro.com
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
EPSS (30 hari)
1,3% peluang dieksploitasi; lebih tinggi dari 69,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
chargepoint home flex cph50 firmware Semua versi sebelum 5.5.4.22

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.