csirt@kutim:~/threat-intel/cve/CVE-2026-39457

Katalog CVE

CVSS 7.8 · High EPSS 0,16%

Kerentanan Stack-based Buffer Overflow pada freebsd. Skor CVSS 3.1 7.8 (High) menurut CISA ADP.

Deskripsi (NVD)

When exchanging data over a socket, libnv uses select(2) to wait for data to arrive. However, it does not verify whether the provided socket descriptor fits in select(2)'s file descriptor set size limit of FD_SETSIZE (1024). An attacker who is able to force a libnv application to allocate large file descriptors, e.g., by opening many descriptors and executing a program which is not careful to close them upon startup, can trigger stack corruption. If the target application is setuid-root, then this could be used to elevate local privileges.

Rincian

Terbit di NVD
30 April 2026
Terakhir diubah
17 Juni 2026
Status NVD
Analyzed
CVSS 3.1
7.8 (High), sumber CISA ADP
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-121: Stack-based Buffer Overflow
EPSS (30 hari)
0,16% peluang dieksploitasi; lebih tinggi dari 4,8% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
freebsd freebsd Versi 13.5
freebsd freebsd Versi 13.5 beta3
freebsd freebsd Versi 13.5 p1
freebsd freebsd Versi 13.5 p10
freebsd freebsd Versi 13.5 p11
freebsd freebsd Versi 13.5 p12
freebsd freebsd Versi 13.5 p2
freebsd freebsd Versi 13.5 p3
freebsd freebsd Versi 13.5 p4
freebsd freebsd Versi 13.5 p5
freebsd freebsd Versi 13.5 p6
freebsd freebsd Versi 13.5 p7
freebsd freebsd Versi 13.5 p8
freebsd freebsd Versi 13.5 p9
freebsd freebsd Versi 14.3
freebsd freebsd Versi 14.3 p1
freebsd freebsd Versi 14.3 p10
freebsd freebsd Versi 14.3 p11
freebsd freebsd Versi 14.3 p2
freebsd freebsd Versi 14.3 p3
freebsd freebsd Versi 14.3 p4
freebsd freebsd Versi 14.3 p5
freebsd freebsd Versi 14.3 p6
freebsd freebsd Versi 14.3 p7
freebsd freebsd Versi 14.3 p8
freebsd freebsd Versi 14.3 p9
freebsd freebsd Versi 14.4
freebsd freebsd Versi 14.4 p1
freebsd freebsd Versi 14.4 p2
freebsd freebsd Versi 14.4 rc1
freebsd freebsd Versi 15.0
freebsd freebsd Versi 15.0 p1
freebsd freebsd Versi 15.0 p2
freebsd freebsd Versi 15.0 p3
freebsd freebsd Versi 15.0 p4
freebsd freebsd Versi 15.0 p5
freebsd freebsd Versi 15.0 p6

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.