csirt@kutim:~/threat-intel/cve/CVE-2026-33774

Katalog CVE

CVSS 5.3 · Medium EPSS 0,29%

Kerentanan Improper Check for Unusual or Exceptional Conditions pada juniper junos. Skor CVSS 3.1 5.3 (Medium) menurut NVD.

Deskripsi (NVD)

An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to bypass the configured firewall filter and access the control-plane of the device. On MX platforms with MPC10, MPC11, LC4800 or LC9600 line cards, and MX304, firewall filters applied on a loopback interface lo0.n (where n is a non-0 number) don't get executed when lo0.n is in the global VRF / default routing-instance. An affected configuration would be: user@host# show configuration interfaces lo0 | display set set interfaces lo0 unit 1 family inet filter input <filter-name> where a firewall filter is applied to a non-0 loopback interface, but that loopback interface is not referred to in any routing-instance (RI) configuration, which implies that it's used in the default RI. The issue can be observed with the CLI command: user@device> show firewall counter filter <filter_name> not showing any matches. This issue affects Junos OS on MX Series: * all versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R2.

Rincian

Terbit di NVD
9 April 2026
Terakhir diubah
8 Juli 2026
Status NVD
Analyzed
CVSS 3.1
5.3 (Medium), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-754: Improper Check for Unusual or Exceptional Conditions
EPSS (30 hari)
0,29% peluang dieksploitasi; lebih tinggi dari 19,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
juniper junos Semua versi sebelum 23.2
juniper junos Versi 23.2 r1
juniper junos Versi 23.2 r1-s1
juniper junos Versi 23.2 r1-s2
juniper junos Versi 23.2 r2
juniper junos Versi 23.2 r2-s1
juniper junos Versi 23.2 r2-s2
juniper junos Versi 23.2 r2-s3
juniper junos Versi 23.2 r2-s4
juniper junos Versi 23.2 r2-s5
juniper junos Versi 23.4 r1
juniper junos Versi 23.4 r1-s1
juniper junos Versi 23.4 r1-s2
juniper junos Versi 23.4 r2
juniper junos Versi 23.4 r2-s1
juniper junos Versi 23.4 r2-s2
juniper junos Versi 23.4 r2-s3
juniper junos Versi 23.4 r2-s4
juniper junos Versi 23.4 r2-s5
juniper junos Versi 23.4 r2-s6
juniper junos Versi 24.2 r1
juniper junos Versi 24.2 r1-s1
juniper junos Versi 24.2 r1-s2
juniper junos Versi 24.4 r1
juniper junos Versi 24.4 r1-s2
juniper junos Versi 24.4 r1-s3

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan