csirt@kutim:~/threat-intel/cve/CVE-2026-17042

Katalog CVE

CVSS 7.3 · High EPSS 0,14%

Kerentanan Out-of-bounds Read pada ibm power system s922 (9009-22g) firmware, ibm power system h922 (9223-22s) firmware +8 lainnya. Skor CVSS 3.1 7.3 (High) menurut us.ibm.com.

Deskripsi (NVD)

IBM Power Systems Firmware FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in host firmware NVRAM parsing. An attacker with root access to a guest partition on an OpenPOWER system can write a specially crafted NVRAM image, causing the host firmware boot stage to crash with possible memory corruption. This condition persists until operator intervention — clearing NVRAM via the service processor — to restore normal operation. This vulnerability only affects OpenPOWER systems; systems running PowerVM are not affected. Successful exploitation results in an integrity and availability impact to the managed system.

Rincian

Terbit di NVD
19 Agustus 2026
Terakhir diubah
25 Agustus 2026
Status NVD
Analyzed
CVSS 3.1
7.3 (High), sumber us.ibm.com
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:L/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-125: Out-of-bounds Read
EPSS (30 hari)
0,14% peluang dieksploitasi; lebih tinggi dari 2,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
ibm power system s922 (9009-22g) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system h922 (9223-22s) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system s914 (9009-41g) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system s924 (9009-42g) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system h924 (9223-42s) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system e950 (9040-mr9) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system e980 (9080-m9s) firmware Versi fw950.00 hingga sebelum fw950.h3
ibm power system ac922 (8335-gth) firmware Versi op940 hingga sebelum op940.a2
ibm power system ac922 (8335-gtx) firmware Versi op940 hingga sebelum op940.a2
ibm power hardware management console (7063-cr2) firmware Versi op940 hingga sebelum op940.82

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.