Lewati ke konten
csirt@kutim:~/threat-intel/cve/CVE-2026-124836

Katalog CVE

CVSS 6.3 · Medium EPSS 0,57%

Kerentanan Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection'). Skor CVSS 4.0 6.3 (Medium) menurut ncsc.ch.

Deskripsi (NVD)

SEPPmail Secure Email Gateway before 15.1.2 inserts message-derived values into LDAP filters used by the ldap_compare and ldap_read mail-rule operations without LDAP filter escaping. An unauthenticated remote sender can alter an LDAP-backed rule query when a deployed rule uses attacker-controlled message data, potentially changing policy decisions or exposing data returned to later rule processing.

Rincian

Terbit di NVD
26 November 2026
Terakhir diubah
26 November 2026
Status NVD
Received
CVSS 4.0
6.3 (Medium), sumber ncsc.ch
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-90: Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
EPSS (30 hari)
0,57% peluang dieksploitasi; lebih tinggi dari 40,9% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 27 Nov 2026, 00:25 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.