csirt@kutim:~/threat-intel/cve/CVE-2026-107202

Katalog CVE

CVSS 9.1 · Critical EPSS 0,78%

Kerentanan Improper Neutralization of Special Elements used in a Command ('Command Injection'). Skor CVSS 3.1 9.1 (Critical) menurut CISA ADP.

Deskripsi (NVD)

A command injection vulnerability exists in the h-ui (version v0.0.25 and below) administrative API due to improper validation of the listen configuration field. When an authenticated administrator submits a value containing shell metacharacters, the application constructs nftables/iptables rule strings using fmt.Sprintf and executes them via bash -c as root. Because the listen field lacks port or format validation, arbitrary OS commands can be injected and executed with root privileges.

Rincian

Terbit di NVD
7 Oktober 2026
Terakhir diubah
7 Oktober 2026
Status NVD
Deferred
CVSS 3.1
9.1 (Critical), sumber CISA ADP
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
EPSS (30 hari)
0,78% peluang dieksploitasi; lebih tinggi dari 54,6% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 8 Okt 2026, 12:26 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.