csirt@kutim:~/threat-intel/cve/CVE-2025-5826

Katalog CVE

CVSS 6.3 · Medium EPSS 0,27%

Kerentanan Misinterpretation of Input pada autel maxicharger ac elite business c50 firmware, autel maxicharger ac pro firmware +7 lainnya. Skor CVSS 3.0 6.3 (Medium) menurut trendmicro.com.

Deskripsi (NVD)

Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Misinterpretation of Input Vulnerability. This vulnerability allows network-adjacent attackers to inject arbitrary AT commands on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ble_process_esp32_msg function. The issue results from misinterpretation of input data. An attacker can leverage this vulnerability to execute AT commands in the context of the device. Was ZDI-CAN-26368.

Rincian

Terbit di NVD
25 Juni 2025
Terakhir diubah
17 Juni 2026
Status NVD
Analyzed
CVSS 3.0
6.3 (Medium), sumber trendmicro.com
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-115: Misinterpretation of Input
EPSS (30 hari)
0,27% peluang dieksploitasi; lebih tinggi dari 18,3% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
autel maxicharger ac elite business c50 firmware Semua versi sebelum 1.39.51
autel maxicharger ac elite business c50 firmware Semua versi sebelum 1.56.51
autel maxicharger ac pro firmware Semua versi sebelum 1.39.51
autel maxicharger ac pro firmware Semua versi sebelum 1.56.51
autel maxicharger ac ultra firmware Semua versi sebelum 1.39.51
autel maxicharger ac ultra firmware Semua versi sebelum 1.56.51
autel maxicharger dc compact mobile firmware Semua versi sebelum 1.39.51
autel maxicharger dc compact mobile firmware Semua versi sebelum 1.56.51
autel maxicharger dc compact pedestal firmware Semua versi sebelum 1.39.51
autel maxicharger dc compact pedestal firmware Semua versi sebelum 1.56.51
autel maxicharger dc fast firmware Semua versi sebelum 1.39.51
autel maxicharger dc fast firmware Semua versi sebelum 1.56.51
autel maxicharger dc hipower firmware Semua versi sebelum 1.39.51
autel maxicharger dc hipower firmware Semua versi sebelum 1.56.51
autel maxicharger dh480 firmware Semua versi sebelum 1.39.51
autel maxicharger dh480 firmware Semua versi sebelum 1.56.51
autel maxicharger single charger firmware Semua versi sebelum 1.39.51
autel maxicharger single charger firmware Semua versi sebelum 1.56.51

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.