csirt@kutim:~/threat-intel/cve/CVE-2025-25037

Katalog CVE

CVSS 9.3 · Critical EPSS 1,6%

Kerentanan Exposure of Sensitive Information to an Unauthorized Actor. Skor CVSS 4.0 9.3 (Critical) menurut vulncheck.com.

Deskripsi (NVD)

An information disclosure vulnerability exists in Aquatronica Controller System firmware versions <= 5.1.6 and web interface versions <= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters.

Rincian

Terbit di NVD
20 Juni 2025
Terakhir diubah
17 Juni 2026
Status NVD
Deferred
CVSS 4.0
9.3 (Critical), sumber vulncheck.com
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-200: Exposure of Sensitive Information to an Unauthorized Actor
EPSS (30 hari)
1,6% peluang dieksploitasi; lebih tinggi dari 74,7% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.