csirt@kutim:~/threat-intel/cve/CVE-2025-11500

Katalog CVE

CVSS 8.7 · High EPSS 0,35%

Kerentanan Insertion of Sensitive Information Into Sent Data. Skor CVSS 4.0 8.7 (High) menurut cert.pl.

Deskripsi (NVD)

Tinycontrol devices such as tcPDU and LAN Controllers LK3.5, LK3.9 and LK4 have two separate authentication mechanisms - one solely for interface management and one for protecting all other server resources. When the latter is turned off (which is a default setting), an unauthenticated attacker on the local network can obtain usernames and encoded passwords for interface management portal by inspecting the HTTP response of the server when visiting the login page, which contains a JSON file with these details. Both normal and admin users credentials are exposed.  This issue has been fixed in firmware versions: 1.36 (for tcPDU), 1.67 (for LK3.5 - hardware versions: 3.5, 3.6, 3.7 and 3.8), 1.75 (for LK3.9 - hardware version 3.9) and 1.38 (for LK4 - hardware version 4.0).

Rincian

Terbit di NVD
16 Maret 2026
Terakhir diubah
17 Juni 2026
Status NVD
Deferred
CVSS 4.0
8.7 (High), sumber cert.pl
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-201: Insertion of Sensitive Information Into Sent Data
CWE-261: Weak Encoding for Password
EPSS (30 hari)
0,35% peluang dieksploitasi; lebih tinggi dari 26,6% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:11 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.