csirt@kutim:~/threat-intel/cve/CVE-2023-46284

Katalog CVE

CVSS 7.5 · High EPSS 0,91%

Kerentanan Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') pada siemens opcenter quality, siemens simatic pcs neo +2 lainnya. Skor CVSS 3.1 7.5 (High) menurut siemens.com.

Deskripsi (NVD)

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

Rincian

Terbit di NVD
12 Desember 2023
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
7.5 (High), sumber siemens.com
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE-787: Out-of-bounds Write
EPSS (30 hari)
0,91% peluang dieksploitasi; lebih tinggi dari 58,7% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
siemens opcenter quality Semua versi
siemens simatic pcs neo Semua versi sebelum 4.1
siemens sinumerik integrate runmyhmi /automotive Semua versi
siemens totally integrated automation portal Versi 14.0 hingga sebelum 15
siemens totally integrated automation portal Versi 15 hingga sebelum 16
siemens totally integrated automation portal Versi 16 hingga sebelum 17
siemens totally integrated automation portal Versi 17 hingga sebelum 18
siemens totally integrated automation portal Semua versi
siemens totally integrated automation portal Versi 18
siemens totally integrated automation portal Versi 18 update_1

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.