csirt@kutim:~/threat-intel/cve/CVE-2023-45794

Katalog CVE

CVSS 8.1 · High EPSS 0,44%

Kerentanan Authentication Bypass by Capture-replay pada siemens mendix. Skor CVSS 3.1 8.1 (High) menurut NVD.

Deskripsi (NVD)

A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.4.0), Mendix Applications using Mendix 7 (All versions < V7.23.37), Mendix Applications using Mendix 8 (All versions < V8.18.27), Mendix Applications using Mendix 9 (All versions < V9.24.10). A capture-replay flaw in the platform could have an impact to apps built with the platform, if certain preconditions are met that depend on the app's model and access control design. This could allow authenticated attackers to access or modify objects without proper authorization, or escalate privileges in the context of the vulnerable app.

Rincian

Terbit di NVD
14 November 2023
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
8.1 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-294: Authentication Bypass by Capture-replay
EPSS (30 hari)
0,44% peluang dieksploitasi; lebih tinggi dari 36,4% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
siemens mendix Versi 7.0.0 hingga sebelum 7.23.37
siemens mendix Versi 8.0.0 hingga sebelum 8.18.27
siemens mendix Versi 9.0.0 hingga sebelum 9.24.10
siemens mendix Versi 10.0.0 hingga sebelum 10.4.0

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.