csirt@kutim:~/threat-intel/cve/CVE-2023-23912

Katalog CVE

CVSS 8.8 · High EPSS 0,96%

Kerentanan Failure to Sanitize Special Elements into a Different Plane (Special Element Injection) pada ui usg firmware, ui usg-pro-4 firmware +8 lainnya. Skor CVSS 3.1 8.8 (High) menurut NVD.

Deskripsi (NVD)

A vulnerability, found in EdgeRouters Version 2.0.9-hotfix.5 and earlier and UniFi Security Gateways (USG) Version 4.4.56 and earlier with their DHCPv6 prefix delegation set to dhcpv6-stateless or dhcpv6-stateful, allows a malicious actor directly connected to the WAN interface of an affected device to create a remote code execution vulnerability.

Rincian

Terbit di NVD
9 Februari 2023
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
8.8 (High), sumber NVD
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-75: Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)
CWE-94: Improper Control of Generation of Code ('Code Injection')
EPSS (30 hari)
0,96% peluang dieksploitasi; lebih tinggi dari 60,4% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
ui usg firmware Semua versi sebelum 4.4.57
ui usg-pro-4 firmware Semua versi sebelum 4.4.57
ui er-10x firmware Semua versi sebelum 2.0.9
ui er-10x firmware Versi 2.0.9
ui er-10x firmware Versi 2.0.9 hotfix2
ui er-10x firmware Versi 2.0.9 hotfix4
ui er-10x firmware Versi 2.0.9 hotfix5
ui er-12 firmware Semua versi sebelum 2.0.9
ui er-12 firmware Versi 2.0.9
ui er-12 firmware Versi 2.0.9 hotfix2
ui er-12 firmware Versi 2.0.9 hotfix4
ui er-12 firmware Versi 2.0.9 hotfix5
ui er-12p firmware Semua versi sebelum 2.0.9
ui er-12p firmware Versi 2.0.9
ui er-12p firmware Versi 2.0.9 hotfix2
ui er-12p firmware Versi 2.0.9 hotfix4
ui er-12p firmware Versi 2.0.9 hotfix5
ui er-4 firmware Semua versi sebelum 2.0.9
ui er-4 firmware Versi 2.0.9
ui er-4 firmware Versi 2.0.9 hotfix2
ui er-4 firmware Versi 2.0.9 hotfix4
ui er-4 firmware Versi 2.0.9 hotfix5
ui er-6p firmware Semua versi sebelum 2.0.9
ui er-6p firmware Versi 2.0.9
ui er-6p firmware Versi 2.0.9 hotfix2
ui er-6p firmware Versi 2.0.9 hotfix4
ui er-6p firmware Versi 2.0.9 hotfix5
ui er-8-xg firmware Semua versi sebelum 2.0.9
ui er-8-xg firmware Versi 2.0.9
ui er-8-xg firmware Versi 2.0.9 hotfix2
ui er-8-xg firmware Versi 2.0.9 hotfix4
ui er-8-xg firmware Versi 2.0.9 hotfix5
ui er-x firmware Semua versi sebelum 2.0.9
ui er-x firmware Versi 2.0.9
ui er-x firmware Versi 2.0.9 hotfix2
ui er-x firmware Versi 2.0.9 hotfix4
ui er-x firmware Versi 2.0.9 hotfix5
ui er-x-sfp firmware Semua versi sebelum 2.0.9
ui er-x-sfp firmware Versi 2.0.9
ui er-x-sfp firmware Versi 2.0.9 hotfix2
ui er-x-sfp firmware Versi 2.0.9 hotfix4
ui er-x-sfp firmware Versi 2.0.9 hotfix5

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan