csirt@kutim:~/threat-intel/cve/CVE-2023-22839

Katalog CVE

CVSS 7.5 · High EPSS 0,63%

Kerentanan NULL Pointer Dereference pada f5 big-ip domain name system, f5 big-ip local traffic manager +32 lainnya. Skor CVSS 3.1 7.5 (High) menurut NVD.

Deskripsi (NVD)

On BIG-IP versions 17.0.x before 17.0.0.2, 16.1.x before 16.1.3.3, 15.1.x before 15.1.8.1, 14.1.x before 14.1.5.3, and all version of 13.1.x, when a DNS profile with the Rapid Response Mode setting enabled is configured on a virtual server with hardware SYN cookies enabled, undisclosed requests cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Rincian

Terbit di NVD
1 Februari 2023
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
7.5 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-476: NULL Pointer Dereference
EPSS (30 hari)
0,63% peluang dieksploitasi; lebih tinggi dari 48,6% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
f5 big-ip domain name system Versi 13.1.0 hingga 13.1.5
f5 big-ip domain name system Versi 14.1.0 hingga sebelum 14.1.5.3
f5 big-ip domain name system Versi 15.1.0 hingga sebelum 15.1.7
f5 big-ip domain name system Versi 16.1.0 hingga sebelum 16.1.3.3
f5 big-ip domain name system Versi 17.0.0 hingga sebelum 17.0.0.2
f5 big-ip local traffic manager Versi 13.1.0 hingga 13.1.5
f5 big-ip local traffic manager Versi 14.1.0 hingga sebelum 14.1.5.3
f5 big-ip local traffic manager Versi 15.1.0 hingga sebelum 15.1.7
f5 big-ip local traffic manager Versi 16.1.0 hingga sebelum 16.1.3.3
f5 big-ip local traffic manager Versi 17.0.0 hingga sebelum 17.0.0.2
f5 big-ip 10000s firmware Semua versi
f5 big-ip 10200v firmware Semua versi
f5 big-ip 10200v-ssl firmware Semua versi
f5 big-ip 12000 firmware Semua versi
f5 big-ip 5000s firmware Semua versi
f5 big-ip 5200v firmware Semua versi
f5 big-ip 5200v-ssl firmware Semua versi
f5 big-ip 7000s firmware Semua versi
f5 big-ip 7200v firmware Semua versi
f5 big-ip 7200v-ssl firmware Semua versi
f5 big-ip i10600 firmware Semua versi
f5 big-ip i10800 firmware Semua versi
f5 big-ip i11600 firmware Semua versi
f5 big-ip i11800 firmware Semua versi
f5 big-ip i15600 firmware Semua versi
f5 big-ip i15800 firmware Semua versi
f5 big-ip i5600 firmware Semua versi
f5 big-ip i5800 firmware Semua versi
f5 big-ip i7600 firmware Semua versi
f5 big-ip i7800 firmware Semua versi
f5 r10600 firmware Semua versi
f5 r10800 firmware Semua versi
f5 r10900 firmware Semua versi
f5 r5600 firmware Semua versi
f5 r5800 firmware Semua versi
f5 r5900 firmware Semua versi
f5 velos bx110 firmware Semua versi
f5 viprion b2100 firmware Semua versi
f5 viprion b2150 firmware Semua versi
f5 viprion b2250 firmware Semua versi
f5 viprion b4300 firmware Semua versi
f5 viprion b4450 firmware Semua versi

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.