CVSS 6.5 · Medium EPSS 0,31%

Kerentanan Improper Preservation of Consistency Between Independent Representations of Shared State pada juniper junos. Skor CVSS 3.1 6.5 (Medium) menurut juniper.net.

Deskripsi (NVD)

An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS) to device due to out of resources. When a device is configured with "service-provider/SP style" switching, and mac-limiting is configured on an Aggregated Ethernet (ae) interface, and then a PFE is restarted or the device is rebooted, mac-limiting doesn't work anymore. Please note that the issue might not be apparent as traffic will continue to flow through the device although the mac table and respective logs will indicate that mac limit is reached. Functionality can be restored by removing and re-adding the MAC limit configuration. This issue affects Juniper Networks Junos OS on QFX5k Series, EX46xx Series: All versions prior to 20.2R3-S5; 20.3 versions prior to 20.3R3-S5; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R3-S3; 21.2 versions prior to 21.2R3-S1; 21.3 versions prior to 21.3R3 on; 21.4 versions prior to 21.4R3 on; 22.1 versions prior to 22.1R2 on.

Rincian

Terbit di NVD
13 Januari 2023
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
6.5 (Medium), sumber juniper.net
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-1250: Improper Preservation of Consistency Between Independent Representations of Shared State
EPSS (30 hari)
0,31% peluang dieksploitasi; lebih tinggi dari 21,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
juniper junos Semua versi sebelum 20.2
juniper junos Versi 20.2
juniper junos Versi 20.2 r1
juniper junos Versi 20.2 r1-s1
juniper junos Versi 20.2 r1-s2
juniper junos Versi 20.2 r1-s3
juniper junos Versi 20.2 r2
juniper junos Versi 20.2 r2-s1
juniper junos Versi 20.2 r2-s2
juniper junos Versi 20.2 r2-s3
juniper junos Versi 20.2 r3
juniper junos Versi 20.2 r3-s1
juniper junos Versi 20.2 r3-s2
juniper junos Versi 20.2 r3-s3
juniper junos Versi 20.2 r3-s4
juniper junos Versi 20.3
juniper junos Versi 20.3 r1
juniper junos Versi 20.3 r1-s1
juniper junos Versi 20.3 r1-s2
juniper junos Versi 20.3 r2
juniper junos Versi 20.3 r2-s1
juniper junos Versi 20.3 r3
juniper junos Versi 20.3 r3-s1
juniper junos Versi 20.3 r3-s2
juniper junos Versi 20.3 r3-s3
juniper junos Versi 20.3 r3-s4
juniper junos Versi 20.4
juniper junos Versi 20.4 r1
juniper junos Versi 20.4 r1-s1
juniper junos Versi 20.4 r2
juniper junos Versi 20.4 r2-s1
juniper junos Versi 20.4 r2-s2
juniper junos Versi 20.4 r3
juniper junos Versi 20.4 r3-s1
juniper junos Versi 20.4 r3-s2
juniper junos Versi 20.4 r3-s3
juniper junos Versi 21.1
juniper junos Versi 21.1 r1
juniper junos Versi 21.1 r1-s1
juniper junos Versi 21.1 r2
juniper junos Versi 21.1 r2-s1
juniper junos Versi 21.1 r2-s2
juniper junos Versi 21.1 r3
juniper junos Versi 21.1 r3-s1
juniper junos Versi 21.1 r3-s2
juniper junos Versi 21.2
juniper junos Versi 21.2 r1
juniper junos Versi 21.2 r1-s1
juniper junos Versi 21.2 r1-s2
juniper junos Versi 21.2 r2
juniper junos Versi 21.2 r2-s1
juniper junos Versi 21.2 r2-s2
juniper junos Versi 21.2 r3
juniper junos Versi 21.3
juniper junos Versi 21.3 r1
juniper junos Versi 21.3 r1-s1
juniper junos Versi 21.3 r1-s2
juniper junos Versi 21.3 r2
juniper junos Versi 21.3 r2-s1
juniper junos Versi 21.3 r2-s2

> Data dari konfigurasi CPE di NVD. Ditampilkan 60 dari 67 konfigurasi; daftar lengkap ada di NVD.

Referensi dan perbaikan