siemens 6gk5204-0ba00-2mb2 firmware, siemens 6gk5204-0ba00-2kb2 firmware, siemens 6gk5204-0bs00-2na3 firmware +2 lainnya
CVSS 9.8 · Critical EPSS 1,1%
Kerentanan Use of Insufficiently Random Values pada siemens 6gk5204-0ba00-2mb2 firmware, siemens 6gk5204-0ba00-2kb2 firmware +3 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| siemens | 6gk5204-0ba00-2mb2 firmware | Semua versi sebelum 3.2.7 |
| siemens | 6gk5204-0ba00-2kb2 firmware | Semua versi sebelum 3.2.7 |
| siemens | 6gk5204-0bs00-2na3 firmware | Semua versi sebelum 3.2.7 |
| siemens | 6gk5204-0bs00-3la3 firmware | Semua versi sebelum 3.2.7 |
| siemens | 6gk5204-0bs00-3pa3 firmware | Semua versi sebelum 3.2.7 |