csirt@kutim:~/threat-intel/cve/CVE-2022-43110

Katalog CVE

CVSS 9.8 · Critical EPSS 0,66%

Kerentanan Improper Access Control. Skor CVSS 3.1 9.8 (Critical) menurut CISA ADP.

Deskripsi (NVD)

Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.

Rincian

Terbit di NVD
22 Agustus 2025
Terakhir diubah
17 Juni 2026
Status NVD
Deferred
CVSS 3.1
9.8 (Critical), sumber CISA ADP
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-284: Improper Access Control
CWE-306: Missing Authentication for Critical Function
CWE-425: Direct Request ('Forced Browsing')
EPSS (30 hari)
0,66% peluang dieksploitasi; lebih tinggi dari 50,2% CVE lain

Produk dan versi terdampak

NVD belum mencantumkan data produk (CPE) untuk CVE ini. Produk yang terdampak biasanya disebut di deskripsi dan di advisory vendor pada daftar referensi.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.