csirt@kutim:~/threat-intel/cve/CVE-2022-39272

Katalog CVE

CVSS 4.3 · Medium EPSS 0,68%

Kerentanan Improper Validation of Specified Quantity in Input pada fluxcd flux2, fluxcd helm-controller +5 lainnya. Skor CVSS 3.1 4.3 (Medium) menurut NVD.

Deskripsi (NVD)

Flux is an open and extensible continuous delivery solution for Kubernetes. Versions prior to 0.35.0 are subject to a Denial of Service. Users that have permissions to change Flux’s objects, either through a Flux source or directly within a cluster, can provide invalid data to fields `.spec.interval` or `.spec.timeout` (and structured variations of these fields), causing the entire object type to stop being processed. This issue is patched in version 0.35.0. As a workaround, Admission controllers can be employed to restrict the values that can be used for fields `.spec.interval` and `.spec.timeout`, however upgrading to the latest versions is still the recommended mitigation.

Rincian

Terbit di NVD
22 Oktober 2022
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
4.3 (Medium), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-1284: Improper Validation of Specified Quantity in Input
EPSS (30 hari)
0,68% peluang dieksploitasi; lebih tinggi dari 51,1% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
fluxcd flux2 Versi 0.1.0 hingga sebelum 0.35.0
fluxcd helm-controller Versi 0.0.2 hingga sebelum 0.24.0
fluxcd helm-controller Versi 0.0.1 alpha1
fluxcd helm-controller Versi 0.0.1 alpha2
fluxcd helm-controller Versi 0.0.1 beta1
fluxcd helm-controller Versi 0.0.1 beta2
fluxcd helm-controller Versi 0.0.1 beta3
fluxcd helm-controller Versi 0.0.1 beta4
fluxcd image-automation-controller Versi 0.1.0 hingga sebelum 0.26.0
fluxcd image-reflector-controller Versi 0.1.0 hingga sebelum 0.22.0
fluxcd kustomize-controller Versi 0.0.2 hingga sebelum 0.29.0
fluxcd kustomize-controller Versi 0.0.1 alpha1
fluxcd kustomize-controller Versi 0.0.1 alpha2
fluxcd kustomize-controller Versi 0.0.1 alpha3
fluxcd kustomize-controller Versi 0.0.1 alpha4
fluxcd kustomize-controller Versi 0.0.1 alpha5
fluxcd kustomize-controller Versi 0.0.1 alpha6
fluxcd kustomize-controller Versi 0.0.1 alpha7
fluxcd kustomize-controller Versi 0.0.1 alpha8
fluxcd kustomize-controller Versi 0.0.1 alpha9
fluxcd kustomize-controller Versi 0.0.1 beta1
fluxcd kustomize-controller Versi 0.0.1 beta2
fluxcd notification-controller Versi 0.0.2 hingga sebelum 0.27.0
fluxcd notification-controller Versi 0.0.1 alpha1
fluxcd notification-controller Versi 0.0.1 alpha2
fluxcd notification-controller Versi 0.0.1 beta1
fluxcd source-controller Versi 0.0.2 hingga sebelum 0.30.0
fluxcd source-controller Versi 0.0.1 alpha1
fluxcd source-controller Versi 0.0.1 alpha2
fluxcd source-controller Versi 0.0.1 alpha3
fluxcd source-controller Versi 0.0.1 alpha4
fluxcd source-controller Versi 0.0.1 alpha5
fluxcd source-controller Versi 0.0.1 alpha6
fluxcd source-controller Versi 0.0.1 beta1
fluxcd source-controller Versi 0.0.1 beta2

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.