powertekpdus basic pdu firmware, powertekpdus pm pdu firmware, powertekpdus piml pdu firmware +4 lainnya
CVSS 7.5 · High EPSS 14,1%
Kerentanan Incorrect Authorization pada powertekpdus basic pdu firmware, powertekpdus pm pdu firmware +5 lainnya. Skor CVSS 3.1 7.5 (High) menurut NVD.
Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| powertekpdus | basic pdu firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | pm pdu firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | piml pdu firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | smart pim firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | smart pos firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | smart pom firmware | Semua versi sebelum 3.30.30 |
| powertekpdus | smart poms firmware | Semua versi sebelum 3.30.30 |