csirt@kutim:~/threat-intel/cve/CVE-2021-45485

Katalog CVE

CVSS 7.5 · High EPSS 3,6%

Kerentanan Use of a Broken or Risky Cryptographic Algorithm pada linux kernel, netapp e-series santricity os controller +24 lainnya. Skor CVSS 3.1 7.5 (High) menurut NVD.

Deskripsi (NVD)

In the IPv6 implementation in the Linux kernel before 5.13.3, net/ipv6/output_core.c has an information leak because of certain use of a hash table which, although big, doesn't properly consider that IPv6-based attackers can typically choose among many IPv6 source addresses.

Rincian

Terbit di NVD
25 Desember 2021
Terakhir diubah
5 Agustus 2026
Status NVD
Analyzed
CVSS 3.1
7.5 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-327: Use of a Broken or Risky Cryptographic Algorithm
EPSS (30 hari)
3,6% peluang dieksploitasi; lebih tinggi dari 89,2% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
linux linux kernel Semua versi sebelum 4.4.276
linux linux kernel Versi 4.5 hingga sebelum 4.9.276
linux linux kernel Versi 4.10 hingga sebelum 4.14.240
linux linux kernel Versi 4.15 hingga sebelum 4.19.198
linux linux kernel Versi 4.20 hingga sebelum 5.4.133
linux linux kernel Versi 5.5 hingga sebelum 5.10.51
linux linux kernel Versi 5.11 hingga sebelum 5.12.18
linux linux kernel Versi 5.13 hingga sebelum 5.13.3
netapp e-series santricity os controller Semua versi
netapp solidfire, enterprise sds & hci storage node Semua versi
netapp solidfire & hci management node Semua versi
netapp brocade fabric operating system firmware Semua versi
oracle communications cloud native core binding support function Versi 22.1.3
oracle communications cloud native core network exposure function Versi 22.1.1
oracle communications cloud native core policy Versi 22.2.0
netapp all flash fabric-attached storage 8300 firmware Semua versi
netapp fabric-attached storage 8300 firmware Semua versi
netapp all flash fabric-attached storage 8700 firmware Semua versi
netapp fabric-attached storage 8700 firmware Semua versi
netapp aff a400 firmware Semua versi
netapp fabric-attached storage a400 firmware Semua versi
netapp hci compute node firmware Semua versi
netapp h300e firmware Semua versi
netapp h300s firmware Semua versi
netapp h410c firmware Semua versi
netapp h410s firmware Semua versi
netapp h500e firmware Semua versi
netapp h500s firmware Semua versi
netapp h610c firmware Semua versi
netapp h610s firmware Semua versi
netapp h615c firmware Semua versi
netapp h700e firmware Semua versi
netapp h700s firmware Semua versi

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.