siemens sinamics sl150 firmware, siemens sinamics sm150 firmware, siemens sinamics sm150i firmware
CVSS 9.8 · Critical EPSS 1,7%
Kerentanan Missing Authentication for Critical Function pada siemens sinamics sl150 firmware, siemens sinamics sm150 firmware +1 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| siemens | sinamics sl150 firmware | Semua versi |
| siemens | sinamics sm150 firmware | Semua versi |
| siemens | sinamics sm150i firmware | Semua versi |