siemens simatic wincc runtime advanced, siemens sinamics sh150 firmware, siemens sinamics sm150i firmware +15 lainnya
CVSS 9.8 · Critical EPSS 2,6%
Kerentanan Access of Memory Location After End of Buffer pada siemens simatic wincc runtime advanced, siemens sinamics sh150 firmware +16 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| siemens | simatic wincc runtime advanced | Semua versi sebelum 16 |
| siemens | simatic wincc runtime advanced | Versi 16 |
| siemens | simatic wincc runtime advanced | Versi 16 update1 |
| siemens | simatic wincc runtime advanced | Versi 16 update2 |
| siemens | simatic wincc runtime advanced | Versi 16 update3 |
| siemens | sinamics sh150 firmware | Semua versi |
| siemens | sinamics sm150i firmware | Semua versi |
| siemens | sinamics gh150 firmware | Semua versi |
| siemens | sinamics gl150 firmware | Semua versi |
| siemens | sinamics gm150 firmware | Semua versi |
| siemens | sinamics sl150 firmware | Semua versi |
| siemens | sinamics sm120 firmware | Semua versi |
| siemens | sinamics sm150 firmware | Semua versi |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Semua versi sebelum 16 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Versi 16 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Versi 16 update1 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Versi 16 update2 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Versi 16 update3 |
| siemens | simatic hmi comfort outdoor panels 15" firmware | Semua versi sebelum 16 |
| siemens | simatic hmi comfort outdoor panels 15" firmware | Versi 16 |
| siemens | simatic hmi comfort outdoor panels 15" firmware | Versi 16 update1 |
| siemens | simatic hmi comfort outdoor panels 15" firmware | Versi 16 update2 |
| siemens | simatic hmi comfort outdoor panels 15" firmware | Versi 16 update3 |
| siemens | simatic hmi comfort panels 4" firmware | Semua versi sebelum 16 |
| siemens | simatic hmi comfort panels 4" firmware | Versi 16 |
| siemens | simatic hmi comfort panels 4" firmware | Versi 16 update1 |
| siemens | simatic hmi comfort panels 4" firmware | Versi 16 update2 |
| siemens | simatic hmi comfort panels 4" firmware | Versi 16 update3 |
| siemens | simatic hmi comfort panels 22" firmware | Semua versi sebelum 16 |
| siemens | simatic hmi comfort panels 22" firmware | Versi 16 |
| siemens | simatic hmi comfort panels 22" firmware | Versi 16 update1 |
| siemens | simatic hmi comfort panels 22" firmware | Versi 16 update2 |
| siemens | simatic hmi comfort panels 22" firmware | Versi 16 update3 |
| siemens | simatic hmi ktp mobile panels ktp400f firmware | Semua versi sebelum 16 |
| siemens | simatic hmi ktp mobile panels ktp400f firmware | Versi 16 |
| siemens | simatic hmi ktp mobile panels ktp400f firmware | Versi 16 update1 |
| siemens | simatic hmi ktp mobile panels ktp400f firmware | Versi 16 update2 |
| siemens | simatic hmi ktp mobile panels ktp400f firmware | Versi 16 update3 |
| siemens | simatic hmi ktp mobile panels ktp700 firmware | Semua versi sebelum 16 |
| siemens | simatic hmi ktp mobile panels ktp700 firmware | Versi 16 |
| siemens | simatic hmi ktp mobile panels ktp700 firmware | Versi 16 update1 |
| siemens | simatic hmi ktp mobile panels ktp700 firmware | Versi 16 update2 |
| siemens | simatic hmi ktp mobile panels ktp700 firmware | Versi 16 update3 |
| siemens | simatic hmi ktp mobile panels ktp700f firmware | Semua versi sebelum 16 |
| siemens | simatic hmi ktp mobile panels ktp700f firmware | Versi 16 |
| siemens | simatic hmi ktp mobile panels ktp700f firmware | Versi 16 update1 |
| siemens | simatic hmi ktp mobile panels ktp700f firmware | Versi 16 update2 |
| siemens | simatic hmi ktp mobile panels ktp700f firmware | Versi 16 update3 |
| siemens | simatic hmi ktp mobile panels ktp900 firmware | Semua versi sebelum 16 |
| siemens | simatic hmi ktp mobile panels ktp900 firmware | Versi 16 |
| siemens | simatic hmi ktp mobile panels ktp900 firmware | Versi 16 update1 |
| siemens | simatic hmi ktp mobile panels ktp900 firmware | Versi 16 update2 |
| siemens | simatic hmi ktp mobile panels ktp900 firmware | Versi 16 update3 |
| siemens | simatic hmi ktp mobile panels ktp900f firmware | Semua versi sebelum 16 |
| siemens | simatic hmi ktp mobile panels ktp900f firmware | Versi 16 |
| siemens | simatic hmi ktp mobile panels ktp900f firmware | Versi 16 update1 |
| siemens | simatic hmi ktp mobile panels ktp900f firmware | Versi 16 update2 |
| siemens | simatic hmi ktp mobile panels ktp900f firmware | Versi 16 update3 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Semua versi sebelum 15.1 |
| siemens | simatic hmi comfort outdoor panels 7" firmware | Versi 15.1 |