csirt@kutim:~/threat-intel/cve/CVE-2021-20588

Katalog CVE

CVSS 9.8 · Critical EPSS 6,9%

Kerentanan Improper Handling of Length Parameter Inconsistency pada mitsubishielectric c controller module setting and monitoring tool, mitsubishielectric cpu module logging configuration tool +39 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.

Deskripsi (NVD)

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

Rincian

Terbit di NVD
19 Februari 2021
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
9.8 (Critical), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-130: Improper Handling of Length Parameter Inconsistency
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
EPSS (30 hari)
6,9% peluang dieksploitasi; lebih tinggi dari 93,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
mitsubishielectric c controller module setting and monitoring tool Semua versi
mitsubishielectric cpu module logging configuration tool Semua versi hingga 1.112r
mitsubishielectric cw configurator Semua versi hingga 1.011m
mitsubishielectric data transfer Semua versi hingga 3.44w
mitsubishielectric ezsocket Semua versi
mitsubishielectric fr configurator Semua versi
mitsubishielectric fr configurator sw3 Semua versi
mitsubishielectric fr configurator2 Semua versi hingga 1.24a
mitsubishielectric gt designer3 Semua versi hingga 1.250l
mitsubishielectric gt softgot1000 Semua versi hingga 3.245f
mitsubishielectric gt softgot2000 Semua versi hingga 1.250l
mitsubishielectric gx configurator-dp Semua versi hingga 7.14q
mitsubishielectric gx configurator-qp Semua versi
mitsubishielectric gx developer Semua versi hingga 8.506c
mitsubishielectric gx explorer Semua versi
mitsubishielectric gx iec developer Semua versi
mitsubishielectric gx logviewer Semua versi hingga 1.115u
mitsubishielectric gx remoteservice-i Semua versi
mitsubishielectric gx works2 Semua versi hingga 1.597x
mitsubishielectric gx works3 Semua versi hingga 1.070y
mitsubishielectric iq monozukuri andon Semua versi
mitsubishielectric iq monozukuri process remote monitoring Semua versi
mitsubishielectric m commdtm-hart Semua versi
mitsubishielectric m commdtm-io-link Semua versi
mitsubishielectric melfa-works Semua versi hingga 4.4
mitsubishielectric melsec wincpu setting utility Semua versi
mitsubishielectric melsoft em software development kit Semua versi
mitsubishielectric melsoft navigator Semua versi hingga 2.74c
mitsubishielectric mh11 settingtool version2 Semua versi hingga 2.004e
mitsubishielectric mi configurator Semua versi
mitsubishielectric mt works2 Semua versi hingga 1.167z
mitsubishielectric mx component Semua versi hingga 5.001b
mitsubishielectric network interface board cc-link Semua versi
mitsubishielectric network interface board cc ie control utility Semua versi
mitsubishielectric network interface board cc ie field utility Semua versi
mitsubishielectric network interface board mneth utility Semua versi
mitsubishielectric px developer Semua versi hingga 1.53f
mitsubishielectric rt toolbox2 Semua versi hingga 3.73b
mitsubishielectric rt toolbox3 Semua versi hingga 1.82l
mitsubishielectric setting/monitoring tools for the c controller module Semua versi
mitsubishielectric slmp data collector Semua versi hingga 1.04e

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.