Kerentanan Relative Path Traversal pada schneider-electric easergy t300 firmware, schneider-electric easergy c5 firmware +15 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.

Deskripsi (NVD)

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.

Rincian

Terbit di NVD
18 Maret 2022
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
9.8 (Critical), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-23: Relative Path Traversal
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
EPSS (30 hari)
6,4% peluang dieksploitasi; lebih tinggi dari 93,5% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
schneider-electric easergy t300 firmware Semua versi hingga 2.7.1
schneider-electric easergy c5 firmware Semua versi sebelum 1.1.0
schneider-electric micom c264 firmware Semua versi sebelum d6.1
schneider-electric pacis gtw firmware Versi 5.1
schneider-electric pacis gtw firmware Versi 5.2
schneider-electric pacis gtw firmware Versi 6.1
schneider-electric pacis gtw firmware Versi 6.3
schneider-electric saitel dp firmware Semua versi hingga 11.06.21
schneider-electric epas gtw firmware Versi 6.4
schneider-electric saitel dr firmware Semua versi hingga 11.06.12
schneider-electric scd2200 firmware Semua versi hingga 10024
rockwellautomation aadvance controller Semua versi hingga 1.40
rockwellautomation isagraf free runtime Semua versi hingga 6.6.8
rockwellautomation isagraf runtime Versi 5.0 hingga sebelum 6.0
rockwellautomation micro810 firmware Semua versi
rockwellautomation micro820 firmware Semua versi
rockwellautomation micro830 firmware Semua versi
rockwellautomation micro850 firmware Semua versi
rockwellautomation micro870 firmware Semua versi
xylem multismart firmware Semua versi sebelum 3.2.0