csirt@kutim:~/threat-intel/cve/CVE-2020-1649

Katalog CVE

CVSS 7.5 · High EPSS 1,1%

Kerentanan pada juniper junos. Skor CVSS 3.1 7.5 (High) menurut NVD.

Deskripsi (NVD)

When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of small fragments requiring reassembly, generating the following error messages: [LOG: Err] MQSS(2): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[2:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(2): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1960, QID 0 [LOG: Err] MQSS(2): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0xc38fb1 [LOG: Notice] Error: /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(2), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D34, 18.2X75-D41, 18.2X75-D53, 18.2X75-D65, 18.2X75-D430 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2 on MX Series; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability.

Rincian

Terbit di NVD
17 Juli 2020
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
7.5 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H · uraikan di kalkulator
EPSS (30 hari)
1,1% peluang dieksploitasi; lebih tinggi dari 64,1% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
juniper junos Versi 17.2
juniper junos Versi 17.2 r1
juniper junos Versi 17.2 r1-s1
juniper junos Versi 17.2 r1-s2
juniper junos Versi 17.2 r1-s3
juniper junos Versi 17.2 r1-s4
juniper junos Versi 17.2 r1-s5
juniper junos Versi 17.2 r1-s7
juniper junos Versi 17.2 r1-s8
juniper junos Versi 17.2 r2
juniper junos Versi 17.2 r2-s11
juniper junos Versi 17.2 r2-s6
juniper junos Versi 17.2 r2-s7
juniper junos Versi 17.2 r3-s1
juniper junos Versi 17.2 r3-s2
juniper junos Versi 17.2 r3-s3
juniper junos Versi 17.3
juniper junos Versi 17.3 r1-s1
juniper junos Versi 17.3 r2
juniper junos Versi 17.3 r2-s1
juniper junos Versi 17.3 r2-s2
juniper junos Versi 17.3 r2-s3
juniper junos Versi 17.3 r2-s4
juniper junos Versi 17.3 r3
juniper junos Versi 17.3 r3-s1
juniper junos Versi 17.3 r3-s2
juniper junos Versi 17.3 r3-s3
juniper junos Versi 17.3 r3-s4
juniper junos Versi 17.3 r3-s7
juniper junos Versi 17.4
juniper junos Versi 17.4 r1
juniper junos Versi 17.4 r1-s1
juniper junos Versi 17.4 r1-s2
juniper junos Versi 17.4 r1-s4
juniper junos Versi 17.4 r1-s5
juniper junos Versi 17.4 r1-s6
juniper junos Versi 17.4 r1-s7
juniper junos Versi 17.4 r2
juniper junos Versi 17.4 r2-s1
juniper junos Versi 17.4 r2-s10
juniper junos Versi 17.4 r2-s2
juniper junos Versi 17.4 r2-s3
juniper junos Versi 17.4 r2-s4
juniper junos Versi 17.4 r2-s5
juniper junos Versi 17.4 r2-s6
juniper junos Versi 17.4 r2-s7
juniper junos Versi 17.4 r2-s8
juniper junos Versi 17.4 r3
juniper junos Versi 18.1
juniper junos Versi 18.1 r1
juniper junos Versi 18.1 r2
juniper junos Versi 18.1 r2-s1
juniper junos Versi 18.1 r2-s2
juniper junos Versi 18.1 r2-s4
juniper junos Versi 18.1 r3
juniper junos Versi 18.1 r3-s1
juniper junos Versi 18.1 r3-s2
juniper junos Versi 18.1 r3-s3
juniper junos Versi 18.1 r3-s4
juniper junos Versi 18.1 r3-s6

> Data dari konfigurasi CPE di NVD. Ditampilkan 60 dari 117 konfigurasi; daftar lengkap ada di NVD.

Referensi dan perbaikan

Sumber: NVD · CVE.org · EPSS. Halaman ini disusun otomatis dari data tersebut; pembaruan terakhir 5 Okt 2026, 20:10 WITA. Kalau sistem di Perangkat Daerah memakai produk ini dan butuh bantuan, laporkan lewat kanal pelaporan.