rockwellautomation eds subsystem, rockwellautomation rslinx, rockwellautomation rslinx enterprise +2 lainnya
CVSS 5.5 · Medium EPSS 2,6%
Kerentanan Improper Restriction of Operations within the Bounds of a Memory Buffer pada rockwellautomation eds subsystem, rockwellautomation rslinx +3 lainnya. Skor CVSS 3.1 5.5 (Medium) menurut NVD.
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| rockwellautomation | eds subsystem | Semua versi hingga 28.0.1 |
| rockwellautomation | rslinx | Semua versi hingga 4.11.00 |
| rockwellautomation | rslinx enterprise | Versi 6.00.00 |
| rockwellautomation | rslinx enterprise | Versi 6.10.00 |
| rockwellautomation | rslinx enterprise | Versi 6.11.00 |
| rockwellautomation | rsnetworx | Semua versi hingga 28.00.00 |
| rockwellautomation | studio 5000 logix designer | Semua versi hingga 32.0 |