CVSS 9.8 · Critical EPSS 11,5%

Kerentanan Improper Input Validation pada rockwellautomation factorytalk linx, rockwellautomation rslinx classic. Skor CVSS 3.1 9.8 (Critical) menurut NVD.

Deskripsi (NVD)

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

Rincian

Terbit di NVD
15 Juni 2020
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
9.8 (Critical), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-20: Improper Input Validation
EPSS (30 hari)
11,5% peluang dieksploitasi; lebih tinggi dari 95,9% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
rockwellautomation factorytalk linx Versi 6.00
rockwellautomation factorytalk linx Versi 6.10
rockwellautomation factorytalk linx Versi 6.11
rockwellautomation rslinx classic Semua versi hingga 4.11.00

> Data dari konfigurasi CPE di NVD.