mobile-industrial-robots mir100 firmware, mobile-industrial-robots mir200 firmware, mobile-industrial-robots mir250 firmware +7 lainnya
CVSS 9.8 · Critical EPSS 1,5%
Kerentanan Use of Hard-coded Credentials pada mobile-industrial-robots mir100 firmware, mobile-industrial-robots mir200 firmware +8 lainnya. Skor CVSS 3.1 9.8 (Critical) menurut NVD.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
· uraikan di kalkulator | Vendor | Produk | Versi terdampak |
|---|---|---|
| mobile-industrial-robots | mir100 firmware | Semua versi hingga 2.8.1.1 |
| mobile-industrial-robots | mir200 firmware | Semua versi |
| mobile-industrial-robots | mir250 firmware | Semua versi |
| mobile-industrial-robots | mir500 firmware | Semua versi |
| mobile-industrial-robots | mir1000 firmware | Semua versi |
| easyrobotics | er200 firmware | Semua versi |
| easyrobotics | er-lite firmware | Semua versi |
| easyrobotics | er-flex firmware | Semua versi |
| easyrobotics | er-one firmware | Semua versi |
| uvd-robots | uvd firmware | Semua versi |