Kerentanan Incorrect Authorization pada schneider-electric ecostruxure control expert, schneider-electric unity pro +21 lainnya. Skor CVSS 3.1 7.3 (High) menurut NVD.

Deskripsi (NVD)

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Rincian

Terbit di NVD
6 Januari 2020
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
7.3 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-863: Incorrect Authorization
EPSS (30 hari)
0,96% peluang dieksploitasi; lebih tinggi dari 60,3% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
schneider-electric ecostruxure control expert Semua versi sebelum 14.1
schneider-electric ecostruxure control expert Versi 14.1
schneider-electric unity pro Semua versi
schneider-electric modicon m580 bmep584040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmeh584040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep586040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmeh586040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep581020 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep582020 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep582040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep583020 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep583040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep584020 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep585040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmeh582040 firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep584040s firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmeh584040s firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmeh586040s firmware Semua versi sebelum 3.10
schneider-electric modicon m580 bmep582040s firmware Semua versi sebelum 3.10
schneider-electric modicon m340 bmxp3420302 firmware Semua versi sebelum 3.20
schneider-electric modicon m340 bmxp342020 firmware Semua versi sebelum 3.20
schneider-electric modicon m340 bmxp342000 firmware Semua versi sebelum 3.20
schneider-electric modicon m340 bmxp341000 firmware Semua versi sebelum 3.20
schneider-electric modicon m340 bmxp3420102 firmware Semua versi sebelum 3.20