csirt@kutim:~/threat-intel/cve/CVE-2019-19699

Katalog CVE

CVSS 7.2 · High EPSS 27,7%

Kerentanan Improper Privilege Management pada centreon. Skor CVSS 3.1 7.2 (High) menurut NVD.

Deskripsi (NVD)

There is Authenticated remote code execution in Centreon Infrastructure Monitoring Software through 19.10 via Pollers misconfiguration, leading to system compromise via apache crontab misconfiguration, This allows the apache user to modify an executable file executed by root at 22:30 every day. To exploit the vulnerability, someone must have Admin access to the Centreon Web Interface and create a custom main.php?p=60803&type=3 command. The user must then set the Pollers Post-Restart Command to this previously created command via the main.php?p=60901&o=c&server_id=1 URI. This is triggered via an export of the Poller Configuration.

Rincian

Terbit di NVD
6 April 2020
Terakhir diubah
17 Juni 2026
Status NVD
Modified
CVSS 3.1
7.2 (High), sumber NVD
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H · uraikan di kalkulator
Jenis kelemahan (CWE)
CWE-269: Improper Privilege Management
EPSS (30 hari)
27,7% peluang dieksploitasi; lebih tinggi dari 98,0% CVE lain

Produk dan versi terdampak

VendorProdukVersi terdampak
centreon centreon Semua versi hingga 19.10

> Data dari konfigurasi CPE di NVD.

Referensi dan perbaikan